Evaluation of an ambulatory system for gait analysis in hip osteoarthritis and after total hip replacement
- PMID: 15196527
- DOI: 10.1016/S0966-6362(03)00093-6
Evaluation of an ambulatory system for gait analysis in hip osteoarthritis and after total hip replacement
Abstract
Spatial and temporal parameters of gait have clinical relevance in the assessment of motor pathologies, particularly in orthopaedics. A new gait analysis system is proposed which consists of (a) an ambulatory device (Physilog) including a set of miniature gyroscopes and a portable datalogger, and (b) an algorithm for gait analysis. The aim of this study was the validation of this system, for accuracy and clinical applicability. Eleven patients with coxarthrosis, eight patients with total hip arthroplasty and nine control subjects were studied using this portable system and also a reference motion analyzer and force plate. The small differences in the stance period (19 +/- ms), stride length and velocity (0.4 +/- 9.6 cm and 2.5 +/- 8.3 cm/s, respectively), as well as thigh and shank rotations (2.4 +/- 4.3 degrees and 0.3 +/- 3.3 degrees, respectively), confirmed good agreement of the proposed system with the reference system. In addition, nearly the same accuracy was obtained for all three groups. Gait analysis based on Physilog was also in agreement with their Harris Hip Scores (HHS): the subjects with lower scores had a greater limp, a slower walking speed and a shorter stride. This ambulatory gait analysis system provides an easy, reproducible and objective method of quantifying changes in gait after joint replacement surgery for coxarthrosis.
Copyright 2003 Elsevier B.V.
Similar articles
-
[Three-D gait patterns before and after total hip arthroplasty].Zhonghua Wai Ke Za Zhi. 2009 Jan 15;47(2):132-5. Zhonghua Wai Ke Za Zhi. 2009. PMID: 19563010 Chinese.
-
A new portable device for assessing locomotor performance.Int J Sports Med. 2008 Apr;29(4):322-6. doi: 10.1055/s-2007-965336. Epub 2007 Sep 18. Int J Sports Med. 2008. PMID: 17879888
-
The influence of walking speed on kinetic and kinematic parameters in patients with osteoarthritis of the hip using a force-instrumented treadmill and standardised gait speeds.Arch Orthop Trauma Surg. 2003 Jul;123(6):278-82. doi: 10.1007/s00402-003-0513-0. Epub 2003 May 14. Arch Orthop Trauma Surg. 2003. PMID: 12748870
-
Post-operative gait analysis in total hip replacement patients-a review of current literature and meta-analysis.Gait Posture. 2012 May;36(1):1-6. doi: 10.1016/j.gaitpost.2011.12.024. Epub 2012 Mar 10. Gait Posture. 2012. PMID: 22410129 Review.
-
The effect of hip arthroplasty on the speed of walking.Pol Orthop Traumatol. 2013 Sep 15;78:201-5. Pol Orthop Traumatol. 2013. PMID: 24042091 Review.
Cited by
-
A Personalized Approach to Improve Walking Detection in Real-Life Settings: Application to Children with Cerebral Palsy.Sensors (Basel). 2019 Dec 3;19(23):5316. doi: 10.3390/s19235316. Sensors (Basel). 2019. PMID: 31816854 Free PMC article.
-
An adaptive gyroscope-based algorithm for temporal gait analysis.Med Biol Eng Comput. 2010 Dec;48(12):1251-60. doi: 10.1007/s11517-010-0692-0. Epub 2010 Nov 2. Med Biol Eng Comput. 2010. PMID: 21042951
-
Gait event detection during stair walking using a rate gyroscope.Sensors (Basel). 2014 Mar 19;14(3):5470-85. doi: 10.3390/s140305470. Sensors (Basel). 2014. PMID: 24651724 Free PMC article.
-
The impact of diabetic foot ulcers and unilateral offloading footwear on gait in people with diabetes.Clin Biomech (Bristol). 2020 Mar;73:157-161. doi: 10.1016/j.clinbiomech.2020.01.014. Epub 2020 Jan 18. Clin Biomech (Bristol). 2020. PMID: 31986461 Free PMC article.
-
Concurrent Validity, Test-Retest Reliability, and Sensitivity to Change of a Single Body-Fixed Sensor for Gait Analysis during Rollator-Assisted Walking in Acute Geriatric Patients.Sensors (Basel). 2020 Aug 28;20(17):4866. doi: 10.3390/s20174866. Sensors (Basel). 2020. PMID: 32872168 Free PMC article.
Publication types
MeSH terms
LinkOut - more resources
Full Text Sources
Medical